Illustrative sample only. All manual excerpts, page references, and findings below are fictional. This is not a review of your selected file.
Atlas.MANUAL REVIEW / SAMPLE
REGULATORY DOCUMENT REVIEW

Manual review
report.

Sample gas transmission O&M manual

REFERENCE SCOPE49 CFR Parts 191 & 192
REVIEW STATUSIllustrative · Not audited
DOCUMENT BASISFictional excerpts only

A clear path from finding to correction.

This sample demonstrates the intended report format: what the manual says, where it says it, which rule applies, and what needs to change or be verified. The three examples do not represent a complete regulatory review.

03Illustrative findings
02High-priority examples
01Evidence request

Finding register

AT-001
Manual review interval is too long

PDF page 8 · Printed page O&M-3

High
AT-002
Loss-of-communications response is incomplete

PDF page 36 · Printed page O&M-31

High
AT-003
Access to operational records needs verification

PDF page 14 · Printed page O&M-9

Review
AT-001 / Conflicting procedureHigh priority

Manual review interval is too long

PDF page 8 Printed page O&M-3Document control · 1.4

Illustrative manual passage

This manual is reviewed and updated every two years.

Issue / review observation

The example procedure permits a two-year review cycle. The rule requires a review and update at least once each calendar year, with no more than 15 months between reviews.

Recommended correction

Set both the calendar-year requirement and the 15-month maximum interval. Identify the responsible role and how the review is recorded.

Reviewer verification

Confirm the actual review history separately. A procedure review alone does not establish whether reviews occurred.

Status: example only · Reviewer: unassigned · Not a compliance determination
AT-002 / Incomplete procedureHigh priority

Loss-of-communications response is incomplete

PDF page 36 Printed page O&M-31Abnormal operations · 6.2

Illustrative manual passage

If communications are lost, notify the supervisor.

Issue / review observation

The example provides a notification step but does not explain how personnel respond to, investigate, and correct loss of communications. This finding assumes paragraph (c) applies to the reviewed transmission operation.

Recommended correction

Define the response, responsibility for investigation, corrective action, and the procedure used to verify safe continued operation.

Reviewer verification

Check linked procedures, control-room instructions, and the exception in § 192.605(c)(5) before accepting the finding.

Status: example only · Reviewer: unassigned · Not a compliance determination
AT-003 / Evidence neededReview priority

Access to operational records needs verification

PDF page 14 Printed page O&M-9Records management · 2.3

Illustrative manual passage

Engineering maintains construction records, maps, and operating history.

Issue / review observation

The example identifies a custodian but does not show how appropriate operating personnel access these records. Additional instructions or linked records may resolve this item.

Recommended correction

Confirm and document how operating personnel obtain the applicable records and current maps during normal work and emergencies.

Reviewer verification

Request the access procedure or supporting record. Do not classify this as a confirmed deficiency solely because it is absent from the example passage.

Status: example only · Reviewer: unassigned · Not a compliance determination

What a production report will document

Document version and hash; readable and unreadable pages; PDF page and printed-page mappings; regulatory snapshot and effective dates; operator scope and unresolved assumptions; coverage by requirement; reviewed evidence and linked attachments; potential findings; reviewer decisions; and an editable corrective-action register.

“Not found” must identify what was searched, including referenced procedures. An unreadable or missing source page must remain a review limitation. State rules and incorporated standards require separate scope and source validation.

Atlas · Illustrative manual review · All excerpts and page references are fictional